42002-0024S Stack Flue Temperature Sensor Replacement for SR200 SR333 SR400 Pool and Spa Heater Electrical Systems

Brand Name : Tian Rui

Model Number : 42002-0024S

Certification : ROHS

Place of Origin : Dongguan, China

MOQ : 100PCS

Price : Negotiable

Payment Terms : D/P, T/T,Paypal, Western Union

Supply Ability : 1000000PCS/Month

Delivery Time : 5-7 Days

Packaging Details : 1000PCS/Bag

Product Name : 42002-0024S Cross Stack Flue Thermistor Temperature Sensors

Fit : Pentair Sta-Rite Max-E-Therm Pool And Spa Heaters Electrical Systems

R200 : 8K OHM

R150 : 29.65K Ohm

R250 : 2.705K Ohm

B150/250 : 5300

Operation Temperature : -30~+300℃

Housing : JM19105 Φ6.35*54.6+S13+24UNF SUS304

Terminal : AMP 250 #22-#18

Cable : PTFE AWG22*1C 320℃

Cable Length : 65mm

Application : Pool Heater

Contact Now

42002-0024S Stack Flue Temperature Sensor Replacement for SR200 SR333 SR400 Pool and Spa Heater Electrical Systems

42002-0024S Stack Flue Temperature Sensor Replacement for SR200 SR333 SR400 Pool and Spa Heater Electrical Systems

42002-0024S Stack Flue Temperature Sensor Replacement for SR200 SR333 SR400 Pool and Spa Heater Electrical Systems

Description of 42002-0024S Stack Flue Temperature Sensor

A stack flue sensor, located on the exhaust elbow of a pool heater, prevents the flue gas output from exceeding 500°F. When this fails, your system will show error codes E05 or E06 to indicate that the stack flue sensor must be replaced. It is designed specifically to replace the Sta-Rite heater stack flue sensor.
This replacement 42002-0024S Stack Flue Sensor from Optimum Pool Technologies is compatible with Pentair MasterTemp pool and spa heater electrical systems, also fits for Pentair Sta-Rite Max-E-Therm pool and spa heater electrical systems model SR200, SR333, SR400

Specification of 42002-0024S Stack Flue Temperature Sensor

Product Name 42002-0024S Cross Stack Flue Thermistor Temperature Sensors
Fit Pentair Sta-Rite Max-E-Therm Pool And Spa Heaters Electrical Systems
R200 8K OHM
R150 29.65K Ohm
R250 2.705K Ohm
B150/250 5300
Housing JM19105 Φ6.35*54.6+S13+24UNF SUS304
Terminal AMP 250 #22-#18
Cable PTFE AWG22*1C 320℃
Cable Length 65mm
Application Pool Heater
Operation Temperature -30~+300℃

Features of 42002-0024S Stack Flue Temperature Sensor

Perfect Fitment — Fits for Pentair MasterTemp pool and spa heater electrical systems, also fits for Pentair Sta-Rite Max-E-Therm pool and spa heater electrical systems model SR200, SR333, SR400.
Function — This Stack Flue Sensor is used to prevent flue gas output from exceeding 500 °F. when it fail to work, your system will display error codes E05 or E06, which indicates that it should be replaced.
Built To Last — Constructed from high standard stainless steel for good rigidity, durability and anti-corrosion. High precision and hardness ensure an unparalleled long lifespan!
Direct Replacement — It is specifically designed to replace the Sta-Rite heater stack flue sensor. Replaces OEM Part No. 42002-0024S.

Note of 42002-0024S Stack Flue Temperature Sensor

Make sure the power is turned off and the heater as cooled for at least 30 minutes before replacing the new sensor.

Quality Certification of 42002-0024S Stack Flue Temperature Sensor


The replacement part is made from durable high quality material and well-tested by the manufacturer.

Wide compatibility with OEM specifications,No harmful chemicals and safe to use.

42002-0024S Stack Flue Temperature Sensor Replacement for SR200 SR333 SR400 Pool and Spa Heater Electrical Systems

42002-0024S Stack Flue Temperature Sensor Replacement for SR200 SR333 SR400 Pool and Spa Heater Electrical Systems

42002-0024S Stack Flue Temperature Sensor Replacement for SR200 SR333 SR400 Pool and Spa Heater Electrical Systems

42002-0024S Stack Flue Temperature Sensor Replacement for SR200 SR333 SR400 Pool and Spa Heater Electrical Systems

42002-0024S Stack Flue Temperature Sensor Replacement for SR200 SR333 SR400 Pool and Spa Heater Electrical Systems

42002-0024S Stack Flue Temperature Sensor Replacement for SR200 SR333 SR400 Pool and Spa Heater Electrical Systems

42002-0024S Stack Flue Temperature Sensor Replacement for SR200 SR333 SR400 Pool and Spa Heater Electrical Systems

42002-0024S Stack Flue Temperature Sensor Replacement for SR200 SR333 SR400 Pool and Spa Heater Electrical Systems

42002-0024S Stack Flue Temperature Sensor Replacement for SR200 SR333 SR400 Pool and Spa Heater Electrical Systems

42002-0024S Stack Flue Temperature Sensor Replacement for SR200 SR333 SR400 Pool and Spa Heater Electrical Systems

42002-0024S Stack Flue Temperature Sensor Replacement for SR200 SR333 SR400 Pool and Spa Heater Electrical Systems

Contact Details:

Andy Wu

Email: andy@tianrui-fuse.com.cn

MP/Whatsapp: +86 13532772961

Wechat: HFeng0805

Skype: andywutechrich

QQ: 969828363


Product Tags:

Stack Flue Temperature Sensor

      

42002-0024S Flue Temperature Sensor

      

Spa Heater NTC Temperature Sensors

      
China 42002-0024S Stack Flue Temperature Sensor Replacement for SR200 SR333 SR400 Pool and Spa Heater Electrical Systems wholesale

42002-0024S Stack Flue Temperature Sensor Replacement for SR200 SR333 SR400 Pool and Spa Heater Electrical Systems Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Dongguan Tianrui Electronics Co., Ltd
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0